Product Description

TYPE UF/ NMC-B
INSULATION: PVC
JACKET: PVC
SIZE: 14 AWG, 2 CONDUCTOR
WITH GROUND, 600 VOLTS, 60ºC WET OR DRY
1.0 SCOPE:
  1.1 This specification covers 2 or 3 conductor cables, with or without a ground wire, having polyvinyl chloride (PVC) insulation and a sunlight-resistant PVC overall jacket, and single conductor cables having a sunlight-resistant PVC insulation.
  1.2 Use:
    UL listed and OSHA acceptable. In accordance with Articles 336 and 339 of the Nat'l Electrical Code (and subject to local code requirements). Type UF cables may be used for underground feeder or branch-circuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multiconductor Type UF (Type NMC-B) cables may also for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays
  1.3
MAXIMUM CONDUCTOR TEMP.
AND VOLTAGE RATING:
TYPE WET DRY VOLTAGE
UF
*NMC-B
60ºC
60ºC
60ºC
60ºC
600V
600V
    * 14 - 10 AWG Only
2.0 CONSTRUCTION:
  2.1 Conductors: (Multiconductor cables only)
    Sizes 14, 12 & 10 AWG: Solid, annealed bare copper per ASTM B-3, UL-493, and UL-719
Sizes 8 & 6 AWG: Concentric, compressed stranded (class B)
  2.2 Conductors: (Single Conductor cables only)
    Sizes 14 - 8 AWG: Solid, annealed bare copper per ASTM B-3, UL-493
Sizes 6 - 4/0 AWG: Concentric, compressed stranded (class B) ASTM B-3 and UL-493
2.3 Insulation:
  For Multiconductor cable only: Polyvinyl chloride (PVC). UL-493 and UL-719
2.4 Ground Wire:
  For 2 or 3 conductor cable with ground. Solid, annealed bare copper per ASTM B-3. Sizes as follows:
 
INSULATED
CONDUCTORS
SIZE (AWG)
GROUND WIRE
SIZE
(AWG)
NDM O.D.
(AWG)
14
12
10
8
6
14
12
10
10
10
.0641|
.0808
.1019
.1019
.1019
2.5 Cable Assembly:
  Multiconductor cables are assembled flat parallel. For cables with ground, the ground wire is placed between two of the insulated conductors.
2.6 Overall Jacket: (integral jacket and insulation for single conductor cable)
  Sunlight, moisture and fungus-resistant. Gray
PVC. UL-493 and UL-719
2.7 Color Code:
  Two-conductor cable: Black, White
Three-conductor cable: Black, White, Red
2.8 Markings:
  Single Conductor Cable: Ink print on jacket (size) AWG Type UF 600 Volts Sunlight Resistant (UL) Multiconductor Cable with Ground: Ink print on jacket (size) AWG/(# of conds.) W.G. Type UF 600V Multiconductor Cable w/o Ground: Ink print on jacket (size) AWG/(# of conds.)

3.0 Cable Data

SIZE
(AWG)
STRAND
NO. / O.D.
(INCHES)
PVC INSUL.
THICK.
(INCHES)
JACKET
THICK.
(INCHES)
APPROX.
OUTSIDE DIAM.
(INCHES)
AMPACITY*
UF OR NMC-B
60ºC
APPROX.
WEIGHT
1K FT.(LBS)
STANDARD
PUTUPS*
SINGLE CONDUCTOR
14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
Solid
Solid
Solid
Solid
7/.0612
7/.0772
7/.0972
19/.0745
19/.0837
19/.0940
19/.1055
.060
.060
.060
.080
.080
.080
.080
.095
.095
.095
.095
-
-
-
-
-
-
-
-
-
-
-
.188
.205
.226
.296
.352
.400
.460
.573
.618
.670
.728
15
20
30
40
55
70
95
125
145
165
195
28
38
52
87
123
183
270
415
508
634
782
500/2500
2500
2500
2500
1000
1000
1000
1000
1000
1000
1000
TWO AND THREE CONDUCTOR - WITHOUT GROUND
14/2
12/2
10/2
8/2
6/2
14/3
12/3
10/3
8/3
6/3
Solid
Solid
Solid
7/.0486
7/.0612
Solid
Solid
Solid
7/.0486
7/.0612
.030
.030
.030
.045
.060
.030
.030
.030
.045
.060
.030
.030
.030
.045
.045
.030
.030
.030
.045
.045
.210 x .435
.220 x .445
.240 x .475
.340 x .700
.410 x .900
.210 x .600
.215 x .640
.245 x .700
.345 x 1.040
.415 x 1.260
15
20
30
40
55
15
20
30
40
55
67
84
114
206
326
98
128
172
308
469
C250/R1500
C250/R1250
C250/R1000
C125/R500
C125/R500
C250/R750
C250/R500
C250/R500
C125/R500
C125/R500
TWO AND THREE CONDUCTOR - WITH GROUND
14/2
12/2
10/2
8/2
6/2
14/3
12/3
10/3
8/3
6/3
Solid
Solid
Solid
7/.0486
7/.0612
Solid
Solid
Solid
7/.0486
7/.0612
030
.030
.030
.045
.060
.030
.030
.030
.045
.060
.030
.030
.030
.045
.045
.030
.030
.030
.045
.045
.210 x .445
.235 x .495
.240 x .570
.340 x .700
.410 x .900
.210 x .650
.225 x .720
.245 x .800
.345 x 1.040
.415 x 1.260
15
20
30
40
55
15
20
30
40
55
78
109
155
230
383
110
147
218
346
519
C250/R1500
C250/R1250
C250/R1000
C125/R500
C125/R500
C250/R750
C250/R500
C250/R500
C125/R500
C125/R500
* Allowable ampacity of not more than three conductors in raceway or cable or
earth (directly buried), based on ambient temperature of 30ºC (86ºF), per Table
310-16 of the 1987 Nat'l Electrical Code (NFPA 70 · 1987
** Standard Put-Ups: